Website Maintenance on October 27 (Japan time)
Our website will be unavailable from October 27th 10:00 until 12:00 (Japan time) due to system maintenance. We apologize for any inconvenience and thank you for your understanding.

Home > Product Information > CataloguesDURAFIDE® PPS > 1130A64 HD9100

HELP

1130A64 HD9100

PRINT
No Word
Counterfeit Products Alert
Item Unit Test Method GF Reinforced
1130A64
Standard, Low Flash
Color No. HD9100
ISO Marking Code ISO11469
(JIS K6999)
>PPS-GF30<
Density g/cm³ ISO 1183 1.57
Water absorption (23°C,24hrs,1mmt) % ISO 62 0.04
Melt viscosity (310℃、1,000/sec) Pa·s ISO 11443 240
Tensile strength MPa ISO 527-1,2 170
Strain at break % ISO 527-1,2 1.9
Flexural strength MPa ISO 178 250
Flexural modulus MPa ISO 178 11,800
Charpy notched impact strength (23℃) kJ/m² ISO 179/1eA 8.0
Temperature of deflection under load (1.8MPa) ISO 75-1,2 265
Coefficient of linear thermal expansion (Normal temperature, Flow direction) x10-5/℃ Our standard 2
Coefficient of linear thermal expansion (Normal temperature, Transverse direction) x10-5/℃ Our standard 4
Electric strength (3mmt) kV/mm IEC 60243-1 15
Volume resistivity Ω·cm IEC 60093 8 x 1015
Volume resistivity (Our standard) Ω·cm -
Relative permittivity (1kHz) IEC 60250 4.2
Relative permittivity (1MHz) IEC 60250 4.2
Dielectric dissipation factor (1kHz) IEC 60250 0.001
Dielectric dissipation factor (1MHz) IEC 60250 0.002
Tracking resistance (CTI) V IEC 60112 125
Arc resistance s ASTM D495 123
Rockwell hardness M(Scale) ISO2039-2 105
Flammability   UL94 V-0
The yellow card File No.     E109088 *2
Appropriate List number of Ministerial Ordinance for Export Trade Control     Item 16 of Appendix -1

If item's description doesn't include test condition, the item is examined at 23 deg. C. (RT)
Details of each property item, test conditions, please see here

*2) Some of the data described on Yellow Card are limited to specific conditions (color, thickness etc.). Please carefully view the detailed descriptions on the Card.

Data of detailed properties

Moldability  Mold Shrinkage  To view the data  
Thermal properties  Coefficient of Linear Thermal Expansion  To view the data  

All figures in the table are the typical values of the material and not the minimum values of the material specifications.
All data shown here are not always applicable to parts used under different conditions. We do not guarantee that these data are directly applicable to the application conditions of users and we ask each user to make his own decision on the application.
For safe handling of materials we supply, it is advised to refer to the Material Safety Data Sheet “SDS” of the proper material.
This brochure is edited based on reference literatures, information and data currently available to us. So the contents of this brochure are subject to change without notice due to new data.